Description Vertical 16-Way PDU (12× C13 4× C19) Dual Branch, 16 A Trips, Neon & Digital Ammeter Key Features Vertical mounting (0 U) designed for rack-side installation — ideal for high-density server cabinets. 16 output sockets: 12 × IEC C13 and 4 × IEC C19 — supports a mix of standard and higher-current rack devices. Two independent branch circuits (6 2 outlets) each protected by a 16 A thermal trip — enhances load distribution and safety. Built-in neon power indicator plus digital ammeter display for real-time current monitoring. Standard 3 m feed lead; plug input options include BS1363 UK, IEC C14, IEC C20, 16 A Commando or 32 A Commando. Rugged construction designed to meet BS EN 60950-compliant standards for professional rack installations. Technical Specifications Specification Details Output Sockets 12 × IEC C13 4 × IEC C19 Branch Circuits 2 branches (6 2 outlets) with 16 A trips Mounting Vertical 0 U rack side Lead Length 3 metre feed lead Plug/Input Options BS1363 UK / IEC C14 / IEC C20 / 16 A Commando / 32 A Commando Indicators & Monitoring Neon power indicator; digital ammeter display Standards BS EN 60950 compliant Why Choose This PDU? This PDU offers an excellent solution for racks hosting both lower-current devices (via C13) and higher-current devices (via C19) in one compact vertical unit. The dual-branch circuit architecture with independent 16 A trips helps prevent overloads on a single circuit while the digital ammeter makes ongoing monitoring effortless. The 0 U format ensures maximum rack equipment space is preserved. Applications & Use-Cases High-density server racks or data cabinets requiring mixed outlet types and monitoring capability. IT, broadcast or comms rooms where real-time rack power usage on each branch must be visible and managed. Network closets or edge data centres where rack space is at premium and vertical side-mount PDUs are preferred. Installations requiring professional-grade power distribution that comply with safety standards and offer monitoring features. Ordering & Custom Options Choose the feed plug/inlet type that matches your site (UK BS1363, IEC C14/C20, 16 A or 32 A Commando). If you require custom lead lengths, mixed socket counts, or additional features (e.g., surge protection), contact us at [email protected] for bespoke quoting. SKU: VIEC12/C194/EN (as listed). Pricing & Delivery Price: £169.00 (standard configuration). Generally in stock with a lead time of 1-2 working days. UK delivery terms apply. Installation & Compatibility Notes Mount along the rack side or rear upright to maximise space efficiency. Ensure your rack feed supply, breaker and socket match the plug/inlet type selected. Monitor each branch load to remain within the 16 A trip limits to avoid nuisance tripping. Use cable management to maintain airflow clearance around rack and PDU. Comply with site earthing and electrical installation regulations for safe operation.
Related products
Sale!